Read full article. Tesla dropped a bomb on the auto market with huge price cuts last week, and now Wall Street is catching up with post-game mmis conduent, if you will. The Company may collect https://forbiddenplateauroadassociation.com/amerigroup-merger-with-wellpoint/12459-cognizant-technical-interview-questions-for-cse.php of Personal Information listed in Cal. In preparation for the transition to a new Fiscal Agent system, including a new provider portal known as MESA, Provider Portal workshop webinars are available throughout October to help providers become familiar with navigating the cinduent system. We deliver real results we are proud of while condkent respectfultransparentand flexible.
If an occlusion is not fully resolved before restarting the infusion, the pump may not re-alarm as expected and may appear to be infusing normally, though may be infusing below the programmed rate or not infusing at all. Baxter has received 51 reports of serious injuries and three reports of patient deaths over five years, potentially associated with this issue.
On December 29, , Baxter sent an Urgent Safety Communication to all affected customers with the following instructions:. Customers with questions about this recall should contact their Baxter sales representative, or Baxter Technical Assistance at choose option 1 Monday — Friday, between am — pm Eastern Time.
Sign up to receive email updates on medical device recalls, safety communications, and other safety information. Use of the affected products may cause serious adverse events, including death. After starting the infusion, verify that drips are flowing in the drip chamber.
At very low flow rates, it may take several minutes to see drops in the drip chamber. If you purchased this product from a distributor, please note that responding at the Baxter customer portal is not applicable. Your cart is empty. Add to Cart. Shop with Confidence Free Shipping. Not ready to buy just yet? Description Features Specifications Literature Description. Warranty: 90 Days - Parts and Labor. Bright, easy to read color display. Can be used with Baxter's standard IV administration sets.
On-board, digital help screens. Quick drug find library search. Configurable dose error reduction software. Single step titration limit.
Flow check at start of infusion. Secondary container infusion check. Bi-directional wireless communication. Comprehensive log analysis software to create CQU reports. With IV Pole Clamp: 5. With IV Pole Clamp: 6.
With IV Pole Clamp: Wireless Battery Module: Less than or equal to 0. Volumetric accuracy based on volume collected over one hour using standard Hospira, Baxter. Total volume up to 9 liters Hospira or 12 liters Baxter. Maximum pump pressure - 36 PSI which can never be obtained with operational occlusion alarm limits.
Frequency: 2. Data Rate: Up to 11 Mbps with automatic fallback. Transmit Power: 16 dBm typical. Receiver Sensitivity: dBm at 11 Mbps. Pre-shared key mode PSK. Alarms and Alerts: Air-In-Line: Dual beam ultrasonic detector alarms for large bubbles but allows smaller bubbles to pass. Audio: Speaker actuated audio alarm, low, medium, and high levels selected through the configurations screen. Battery Missing: Pump does not detect battery attached.
Depleted Battery: Pump stops running, alarms for 3 minutes. Dose Rate Limit Exceeded: The pump will run with a soft dose rate exceeded after a double confirmation, it will not run with a hard dose rate exceeded, rates must be reset within hard limits.
Downstream Occlusion: Automatic restart occurs after the downstream occlusion is cleared. Inactivity: Actuates after the pump has been inactive for 2 minutes. In Stop: Load set. In Stop: Open side clamp. In Stop: Push run. Low Battery: Less than 30 minutes of battery power remain. Shut Door. Side Clamp Closed: Pump stopped. System Error. Upstream Occlusion. Very Low Battery: Less than 15 minutes of battery power remain. Timekeeping: Real time clock, battery backed, 10 year life.
Separate pump and drug library history logs, minimum of 96 hours each under extensive logging intensive operating conditions. Type BF Applied Part. Continuous Operation. Additional Asynchronous Serial Port Expansion bus available at battery terminals. Wireless - Customer Reviews. This product is eligible for free returns!
Item arrives secured to a pallet and delivered up to address. Freight delivery does not include bringing the shipment inside of the address, unpacking, or disposing of packing material. Customer is responsible for moving the shipment into their address, unpacking, and disposing of packing material. Includes unloading, unpacking, disposing of packing material, and placement of your items in the location of your choice.
Inside delivery does not include training, assembly, or installation. Does not apply to hospital beds shipping to residential addresses. Customer is responsible for ensuring that the items can be delivered in the desired location without issue.
The carrier is not able to remove old equipment or obstacles. Haven't purchased yet? We will match and try to beat our competitors' price. Please find the condition of the item you have below: Factory New Items are warrantied by and through the manufacturer. All warranty claims need be processed through the original manufacturer.
MFI is available to assist with any manufacturer warranty claims. Factory Refurbished are warrantied by and through the manufacturer. Warranty claims should be submitted through our online service ticket request. After expiration of warranty, MFI is available to assist with telephonic technical support free of charge. Please request service here. Earn rewards points Sign up for an account Earn rewards points.
We recently created a new training video to take a closer look at the different features of the Sigma pump, how to use the pump, and a few tricks and tips that will help healthcare workers and educators be able to use this Baxter IV pump effectively. The Sigma Spectrum is a popular infusion pump in the healthcare market and has maintained this position of popularity for a few main reasons:.
As with all specialized medical equipment, specialized training is needed for the clinical staff to use the Sigma Spectrum — Baxter IV Pump correctly. Topics covered in this Sigma Spectrum Infusion Training Video include initial set-up, programming, and running a variety of infusions. The more specialized clinical functions of the device are also covered, such as:.
This ensures that the unit is working the same way that it originally left the manufacturer. After the spectrum infusion system is working like new it undergoes a special cosmetic restoration process. The Spectrum is cleaned, minor scratches and dents are repaired, it's painted, and new decals are replaced if necessary.
After this strenuous refurbishing process, the infusion system functions and looks like new. Soma Tech Intl is ISO certified and ensures that the best quality is given to all capital medical equipment that they sell.
Before the pump is labeled patient-ready and packed up for shipment, it goes through one last quality control test that makes sure all aspects are again working as they should. Soma Tech Intl is also actively looking to purchase a Sigma Spectrum infusion pump. If you or your facility is looking to sell your Spectrum , be sure to contact Soma Tech Intl.
Soma has a dedicated and experienced purchasing department that helps you through the entire process. This also ensures that your medical facility gets top dollar for your equipment. Soma Tech Intl also gives the option for trade-in credit on your medical equipment.
Soma Tech Intl offers a wide range of infusion pumps. If you have any questions about any of our infusion systems or need a quick quote, call GET-SOMA and one of our knowledgeable sales representatives will help you. SOMA 1.
Home > Products > Infusion Pumps > Baxter Sigma Spectrum Previous Next Baxter Sigma Spectrum Are available Brand:Baxter Type:Infusion Pumps Buy Sell Rent Need help . The Spectrum IQ Infusion System automatically defaults to the installed drug library and wirelessly updates the drug library,without requiring clinicians to take extra steps to use pump . Infusion Systems and Specialized Patient Monitoring. Large Volume Pumps (LVP) are used to deliver medication and solutions through various routes (e.g. Intravenous and epidural) for .